Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
CVE Status: Modified
Attribute | Value |
---|---|
Attack Complexity | LOW |
Attack Vector | ADJACENT_NETWORK |
Availability Impact | HIGH |
Base Score | 8.2 |
Base Severity | HIGH |
Confidentiality Impact | NONE |
Integrity Impact | LOW |
Privileges Required | NONE |
Scope | CHANGED |
User Interaction | NONE |
Vector String | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H |
Exploitability Score | 2.8 |
Impact Score | 4.7 |
Source | [email protected] |
Type | Primary |