Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don't zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). Additionally the granularity of the grant table doesn't allow sharing less than a 4K page, leading to unrelated data residing in the same 4K page as data shared with a backend being accessible by such backend (CVE-2022-33741, CVE-2022-33742).
CVE Status: Modified
Attribute | Value |
---|---|
Attack Complexity | LOW |
Attack Vector | LOCAL |
Availability Impact | HIGH |
Base Score | 7.1 |
Base Severity | HIGH |
Confidentiality Impact | HIGH |
Integrity Impact | NONE |
Privileges Required | LOW |
Scope | UNCHANGED |
User Interaction | NONE |
Vector String | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H |
Exploitability Score | 1.8 |
Impact Score | 5.2 |
Source | [email protected] |
Type | Primary |